FXII Chiller Revision: 05 March 25, 2013 9
Specifications
Set point range Cool Mode 38°F-58°F or
3.3°C-14.4°C
Heat Mode 95°F to 120°F or
35°C to 48.9°C
Sensor accuracy 2°F at 77°F
Low voltage limit 115 VAC units 75VAC
Low voltage limit 230 VAC units 175VAC
Line voltage limit 240VAC
Frequency 50 or 60 Hz
Fan output MAX
(Connect to Sea Water Pump) 4 Amps
Valve output MAX
(Connect to optional electric heater) 10 Amps
Circulating Pump output MAX ¼ HP at 115 VAC
½ HP at 230 VAC
Compressor output 1HP at 115 VAC
2HP at 230 VAC
Minimum operating temperature 0°F
Maximum operating temperature 180°F
Maximum RH conditions 99% Non-condensing
Maximum length of the display cable 75 Feet
Maximum length of the sensor cable 50 Feet