FXII Chiller Revision: 05 March 25, 2013 4
Operating Screen
Water Inlet Temperature Water Outlet Temperature
Heating
Temperature Set Point or
Cooling
Operating Status Icon
Mode Selection
To change from heating to cooling or cooling to heating, tap the mode select
button. Set the desired loop water temperature by tapping the up or down button. The
system will provide cooling or heating as selected.
Operation
The control will automatically operate the circulating pump, sea water pump,
compressor and heater or valve as necessary. Inlet temperature must be more than two
degrees from the set point for operation to occur. In heat mode, temperatures must be
below set point and in cool mode temperatures must be above the set point. Temperatures
must be above 33°F for any operation. Operating output conditions are indicated in the
icon at the center of the display.
CW is the closed circulating water loop. When the pump is on, the icon
will animate and show water flow in the system. If the flow switch opens,
or the pump is off, the pipe will appear empty.
This is the compressor symbol. When the compressor is running, the
symbol will look like an operating piston.
SW is the sea water pump. When the pump is on, the symbol will animate and
show the pump operating and water flowing. When the sea water pump is off, the
pipe will appear empty and the pump will not spin.
This is the electric heat symbol. This symbol will appear in heat mode in
place of the compressor if the optional electric heater is installed and
selected in the programmable parameters. The animation will look like
heat rising from the element when the heater is on.